top of page

Dental Monitoring Systems

Be Sure, Be PARASURE

Be Sure, Be PARASURE

ParaSure has a comprehensive range of products suitable for dental practices for both washing and sterilization processes. The ParaSure DentaClean system is designed to simulate the small instruments and baskets inside a table-top washer, providing an easy way to assess the efficacy of soil removal.

​

Specifically packaged ParaSure DentaPro offers the user a cost effective way to ensure that there are no protein residues left on the instruments or surfaces after processing. Bowie and Dick tests, helix devices for small sterilizers (type B) are also available, along with specifically calibrated chemical indicators to monitor the steam sterilization process. The indicators also have an adhesive backing, making them easy to use in documentation systems.

ParaSure DentaPro

The ParaSure DentaPro is the only protein detection test for the dental market with sensitivity to 1mg of protein with no incubation. Each vial is individually wrapped and comes with its own short swab. Once the swab is inserted into the vial the result is immediate.

ParaSure DentaClean

ParaSure DentaClean offers a unique and cost effective option for all dental practices to ensure their decontamination process and soil removal efficacy is in accordance with HTM 01-05. The DentaClean polypropylene basket simulates a bur basket inside which is placed a ParaSure Cleaning Efficacy Indicator.

ParaSure Cleaning Efficacy Indicators

ParaSure Cleaning Efficacy Indicators, when used in conjunction with the range of ParaSure Process Challenge Devices prove the efficacy of the mechanical cleaning system (ultrasonic, washer disinfector and AER) through the visual inspection of soil removal.

ParaSure Standard Lumen Process Challenge Device

The ParaSure Standard Lumen Process Challenge Device represents Minimal Invasive Surgical instrumentation and when used in conjunction with the ParaSure CEI represents a consistently repeatable challenge to cleaning efficacy.

ParaSure Type Four Multi-Parameter Indicators for Steam Sterilization

ParaSure Type 4 Multi-Parameter Indicators for Steam Sterilization conforms to EN ISO 11140-1 Type 4 and are supported by technical certificates. These laminated indicators show a clear colour change from blue to black in the correct conditions.

ParaSure Type 6 Emulating Indicators for Steam Sterilization

ParaSure Type 6 Emulating Indicators for Steam Sterilization conform to EN ISO 11140-1 Type 6 and are available in all calibrations, supported by technical certificates to confirm the precision of the calibration.

ParaSure Type 6 Self-Adhesive Indicators for Steam Sterilization

ParaSure Type 6 Self-Adhesive Indicators for Steam Sterilization have an adhesive backing to ensure easy placement into record systems or patient records and conform to EN ISO 11140-1 Type 6. They are available in all calibrations, supported by technical certificates.

ParaSure EN 867-5 Helix Device with 250 Indicators

The ParaSure EN 867-5 Helix device is used for the daily testing of the mechanical function of small vacuum-assisted steam sterilizers as specified in EN ISO 13060 Type B. It is an indicator placed into a hollow lumen challenge device of 1.5 metres in length with a 2 mm inner diameter.

ParaSure Autoclave Tape for Steam Sterilization

ParaSure Autoclave Tape for Steam Sterilization conforms to ENISO 11140-1 Class 1. This non-toxic, latex-free autoclave tape has an easy to interpret colour change and clear labelling showing the batch number and expiry date. Available in 19mm and 25mm widths.

ParaSure Face Shield

ParaSure offers a disposable face shield to protect personnel during routine procedures or daily work. The material used is anti-fog and latex free, is comfortable and long enough to avoid the need for face masks. The ParaSure face shield can also be used over spectacles.

Ultrasonic Cavicheck

Monitoring the energy of ultrasonic bath for cleaning of surgical instrument.

ParaSure Ultrasonic Foil Test

Ultrasonic foil tests consist of foil-based material. If the appliance operates correctly, the cavitation energy emitted from sources will dismember the foil inside the frame.